Leica TDA5005 ATR Total Station
New standards – more applications
The Leica Industrial Theodolites and Total Stations of the TPS5000 series set new standards in portable, large-scale coordinate measurement. Based on proven technology, unrivalled precision and optics, the Leica Theodolites have become standard in Aerospace alignment applications. By incorporating a precision distance meter and automation features, the so-called Total Station has spread into every industry as a truly largescale PCMM solution for tooling, inspection and assembly. Their flexibility together with a large choice of both software and hardware solutions give you a wider perspective – in all dimensions.
Features:
- Highest angle and distance accuracy
- Completely open and programmable software interface
- Motorization & Automation
- Minimal set-up time within just a few minutes
- Wide range of accessories and targets
- Extended specifications for environmental conditions
- Measurement range beyond 200 m with TDA5005
- Remote control option with TDA5005
- Built-In Automatic Target Recognition ATR within the TDA5005
Specifications:
| Angular measurement | |
| Standard deviation per ISO17123-3, 1 σ 1) 0.5“ (0.15 mgon) | 0.5“ (0.15 mgon) |
| Units of measurement | 360˚ sexagesimal, 400 gon 360˚ decimal, 6400 mil |
| Display (smallest selectable unit) |
0.01 mgon; 0.1“, 0.00001˚ 0.00001 mil |
| Automatic reference to the horizon (2-axis liquid compensator) | |
| Working range, longitudinal/lateral | 3' (0.055 gon) |
| Setting accuracy | ≤ 0.3“ (0.1 mgon) |
| Displays | |
| LCD (liquid crystal display) | 8 rows of 35 characters each 6 status fields |
| Data storage and interfaces | PCMCIA memory card RS232 programmable interface |
| Motor and fine drives | |
| Fine drives | Coarse/fine, motorised, infinite, slip coupling |
| Motor | Speed of rotation: 45 ˚/s (50 gon/s) Positioning accuracy: 0.8” (0.2 mgon) |
| Power supply | Plug-in battery pack: 12 V/1.8 Ah, rechargeable External power source: Any 12 V battery (e.g. GEB70) or mains power supply |
| Temperature range | Working: –20˚ C to +50˚ C (–4˚ F to +122˚ F) Storage: –40˚ C to +70˚ C (–40˚ F to +158˚ F) |
| Point accuracy (total RMS ≈1 σ) at 20 m (65 ft) measuring volume | ≤ 0.3 mm (0.012”) |
| Distance measurement | |
| Standard deviation (absolute) per ISO17123-4, 1 σ | 1 mm + 2 ppm (0.04” + 2 ppm) over the entire measurement range |
| Typical distance accuracy at 120 m (365 ft) measuring volume | Reflective tape: ± 0.5 mm (0.02”) Corner cube reflector: ± 0.2 mm (0.008”) |
| Units of measurement | m, mm, feet, inch |
| Display | 0–5 decimal places, dependent on the selected unit |
| Reflectors (selectable) | Prisms, Corner Cube Reflectors CCR (1.5“ diameter), Leica reflective tapes, 360˚ prisms |
| Measurement range with CCR (dependent on atmospheric conditions) | 2 to 600 m (6 to 1’900 ft) |
| Measurement range with reflective tapes (dependent on target size) | 2 to 180 m (6 to 600 ft) |
| ATR – Automatic Target Recognition | |
| Tracking speed lateral (linear) | 3 m/s (10 ft/s) at a distance of 10 m (33 ft) |
| Tracking speed longitudinal | 4 m/s (13 ft/s) |
| Measurement range | 2.5 to 1’000 m (8 to 3’300 ft) |
| Safety Class | Laser Class I as defined by IEC 825-1 or EN 60825-1 FDA 21 CFR Ch. I §1040 |
| Weight (w/o battery, tribrach) | 7.5 kg (17,5 lbs) |
| Manufacturer | Leica |
|---|